What is homogeneous tempered glass? What are its advantages?
Homogeneous tempered glass is a product that has undergone homogenization treatment on tempered glass. Currently, there is a national standard for this product. The homogenization process involves placing tempered glass in a homogenization furnace, maintaining a heating rate of no more than 1.5℃/min, and continuously heating it to around 298℃ for several hours. This causes the NiS inside the tempered glass to change phase or hard impurities to expand, leading to glass breakage. After it gradually cools down, the intact glass is removed. This process is also vividly referred to as detonation treatment.

The causes of tempered glass self-explosion
The reason for the self-explosion of tempered glass is that sulfur and nickel impurities are mixed in during the glass manufacturing process, and nickel sulfide is formed at high temperatures. Nickel sulfide has two types of crystals. At high temperatures (t>380℃), it is the α phase, and at low temperatures, it is the β phase. During tempering, due to rapid cooling, the α phase did not have enough time to transform into the β phase. During use, the α phase, which is metastable at room temperature, gradually transforms into the stable β phase. It is only when there is a volume expansion of approximately 4% that the tempered glass self-exploexploes.
The benefits of tempered glass after homogenization treatment
The function of the homogenizing furnace is to completely transform the α phase of nickel sulfide into the low-temperature stable β phase. The glass that comes out of the furnace will no longer be able to self-explode (detonate), effectively ensuring that tempered glass has no possibility of self-explosion.

Why does tempered glass need to undergo homogenization treatment? What is the process of homogenization treatment?
The main purpose of homogenizing tempered glass is to reduce the self-explosion rate of tempered glass. In the national standard for tempered glass, "GB15763.2-2005", the "self-explosion" of tempered glass is explained. When nickel sulfide crystals appear in the tensile stress zone of tempered glass and the crystals transform, self-explosion will occur. Therefore, a glass tempering furnace is generally used to homogenize the glass, enhancing its safety in use.
The probability of self-explosion of tempered glass allowed by the industry is 0.1% to 0.3%, which is inevitable due to the characteristics of the glass itself. The main way to solve this phenomenon is to control the quality of the original glass sheet and keep the stress of tempered glass within an appropriate range. Homogenization treatment is recognized as an effective method to solve the problem of self-explosion.
The process of homogenization treatment: Inspection of the homogenization treatment process
The process of homogenization treatment
The homogenization process of tempered glass consists of three stages: heating up, holding at temperature, and cooling down, which is similar to the tempering process of the original sheet.
1. Heating stage:
The temperature rise starts from the ambient temperature where the glass is located and stops when all the glass reaches 280℃. The surface temperature of the glass must not exceed 320℃, and the time when the surface temperature of the glass exceeds 300℃ should be shortened as much as possible. This requires us to heat up more evenly.
2. Insulation stage:
All the glass should be kept warm after reaching 280 degrees Celsius for at least two hours, maintaining the surface temperature of the glass within a range of 10 degrees Celsius around 290 degrees Celsius.
3. Cooling stage:
After the heat preservation is completed, it enters the cooling stage, allowing the glass to cool to room temperature. When the temperature inside the furnace drops to 70℃, the furnace door can be opened to stop the cooling output.
Inspection of the homogenization treatment process
General inspections are carried out by qualified third-party supervision institutions, typically including on-site inspections of the homogenization process and finished product inspections of homogenized glass. These include checks on parameters such as intervals, positions, types, materials, and temperatures during the operation process, as well as tests on the relevant properties of the finished tempered glass. The validity period of the report issued by the inspection is one year.
This inspection can standardize the enterprise's homogenization treatment operation process, further regulate the enterprise's production behavior, ensure the quality of homogenized tempered glass and enhance the safety of product use.