Glass curtain walls, as an indispensable decorative element in modern urban architecture, not only enhance the aesthetic value of buildings but also play a significant role in multiple aspects such as functionality, energy conservation and structure. However, with its wide application, a series of potential safety hazards have gradually come to light, such as glass self-explosion, insufficient fire resistance, light pollution problems, aging of structural adhesives, failure of supporting structures, and loosening of fixing devices. These hidden dangers not only threaten public safety, but also become increasingly prominent as the service life of the curtain wall increases. Therefore, we must face up to these problems and take effective measures to prevent and solve them.

▍ Self-explosion Issues and Prevention
The self-explosion of glass curtain walls has long been a challenge faced by the glass and glass curtain wall industry. This spontaneous cracking phenomenon occurs without direct mechanical external force and is closely related to the nickel sulfide crystals contained in the glass and the degree of tempering. To effectively control the self-explosion phenomenon of glass curtain walls, we can take the following measures:
Control the problem from the source, that is, strictly control the nickel content in the glass;
The freezing of nickel sulfide is reduced by adopting semi-tempered laminated glass.

Replace single-pane tempered glass and tempered insulating glass with laminated glass. In this way, even if the glass breaks, the fragments will adhere to the film, thus avoiding the formation of glass rain and causing harm to personnel.
Continuous monitoring should be carried out after the installation of the curtain wall glass. Once any abnormality is detected, it should be replaced immediately to ensure safety.
Prevention of failure of supporting structures
The stability of the supporting structure of the glass curtain wall, which includes the fixing devices and frames that support the glass, is of vital importance. If the frame structure fails or there are unforeseen flaws in the fixing devices, it may lead to the fall of the curtain wall glass. The unreasonable frame structure design cannot withstand the gravity of the building, thereby causing deformation and eventually leading to the breakage and fall of the glass. Therefore, glass curtain walls must have sufficient load-bearing capacity, rigidity, stability, and displacement capacity relative to the main structure.
To prevent the failure of the supporting structure of glass curtain walls, designers should conduct in-depth analysis of the force conditions of the components in the early stage, reasonably select calculation parameters, and strictly follow the current norms and standards. During the construction and installation process, a detailed inspection of the fixing devices and frame structure should be carried out, and measures should be taken to prevent the fastening bolts from slipping off. Once abnormal deformation, detachment or cracking is found in the supporting structure, local wall surfaces, etc., or after natural disasters such as typhoons occur, a comprehensive inspection of the main load-bearing components, connecting components and connecting bolts of the glass curtain wall should be carried out.
Fire prevention measures have been strengthened
The glass curtain wall itself is not non-combustible. Its fire resistance performance, fire resistance stability and fire resistance insulation all need to be improved. In the event of a fire, glass curtain walls may soften or even melt, causing the glass to break and thus affecting the safety of the building. However, from the perspective of fire safety, we hope that the glass curtain wall can remain stable during a fire, without cracking or falling off, to ensure the safety of people and property. To achieve this goal, we can take a variety of measures, such as using fire-resistant glass to enhance its fire resistance, improving the advancement of fire-fighting equipment to accelerate the fire-fighting process, or adopting other technical means to enhance the fire resistance and heat insulation capabilities of glass curtain walls.